SteveCAD model creation and geometry inspection

Process demonstration — unvalidated engineering estimates. Assumptions, transferred estimates and unresolved requirements remain explicit. This readable view does not change the source evidence.

Earlier completed study work, shown alongside the later analysis continuation. This is a contextual CAD model, not the mesh used for the pipe-beam calculations.

The CAD model contains 25 rods with one provisional cubic-Bezier bow and no spacer-grid geometry. The inspection covers one rod pair at 50% nominal gap closure; it does not establish all-pairs clearances or contact behavior.

Model definition

QuantityValueOrigin
Rod array5 × 5; 24 straight rods and one bowed rodNative SteveCAD build
Rod outside diameter9.5 mmSupplied
Rod pitch12.6 mmSupplied
Centerline span1000 mmProvisional assumption
Wall thickness0.57 mmProvisional assumption
Nominal closure50%One geometry demonstration case
Spacer gridNot modeledUnresolved geometric/support limitation
Native build result25 solids; 49 features reported OKProvider observation

Clearance inspection of the exported geometry

MeasurementObservedMeaning
Closest surface gap1.55000 mmOne bowed/adjacent rod pair
Target gap1.55 mmProvisional 50% closure geometry
Comparison tolerance0.005 mmDeclared numerical comparison
Overlap volume0 mm³No overlap reported for this pair
Model recreated for inspectionNoExisting STEP reused
FEA/thermal solver run at this stageNoGeometry inspection only

Applicability limits

Limitation
One rod pair in one provisional 50% closure geometry; not an all-pairs clearance survey or the full closure case matrix.
No spacer grid, spring/dimple, support or coolant geometry; physical feasibility remains unresolved.
Cubic Bezier bow differs from the currently proposed sinusoidal analysis basis; coordinate frames also differ by a translation. A must resolve the model choice.
Both native geometry tools use OpenCASCADE-derived kernels; this is separate-provider readback, not independent-kernel validation.
The provider auxiliary centreDistance field is retained in raw evidence but is not used as pitch or gap; its geometric reference is not established here.
Initial runner CLI summary raised KeyError after the run completed because the start response is a receipt, not the durable run record. Reconciled this exact run; no tool dispatch replay.
Source record and traceability

Download original machine-readable record

SHA-256: 5c267b318032b36781c74b661cea1d79ce49ab15f944ec9ed75bb538f31d3aea

Presentation generated from this retained record. Historical status fields describe the source revision; later review decisions are explained on the engineering review page.