  "scope": "Proposal arithmetic for engineer review only; not a study result or calibrated grid prediction",
  "model_card": "basis/eol-reference-model-proposal-r1.json",
  "reference_fluence_n_m2": 6e+24,
  "published_fit_stress_ratio": 0.5021626470260343,
  "unity_anchored_alternative_ratio": 0.5488116360940265,
  "slope_sensitivity_not_confidence_interval": [
    {
      "slope_m2_n": 7.5e-26,
      "ratio": 0.5834297587339227
    },
    {
      "slope_m2_n": 1e-25,
      "ratio": 0.5021626470260343
    },
    {
      "slope_m2_n": 1.25e-25,
      "ratio": 0.43221539575802853
    }
  ],
  "exposure_duration_days_if_flux_is_constant_within_source_range": [
    385.8024691358025,
    462.962962962963
  ],
  "conditional_preload_mapping_N": {
    "spring": 2.5108132351301715,
    "dimple_1": 1.2554066175650858,
    "dimple_2": 1.2554066175650858
  },
  "limitations": "Extra numerical digits support reproducibility, not empirical precision. Time bounds are derived equivalent exposures, not observed operating dates."
}